It is quite easy to create your raid devices from the gui. Software raid 10 in solaris 11, multipath, and a few. A redundant array of inexpensive disks raid allows high levels of storage reliability. When checking status of raid5 volumes, you need to check both the raid5. Creating raid5 volumes solaris volume manager administration. Software raid is one of the greatest feature in linux to protect the data from disk failure. Raidz1, similar raid5, highest capacity, lowest cost, do not use with more than 5 disks or high capacity disks due to long. In this article we are going to learn how to configure linux lvm in software raid 5 partition. There are all the normal risks of any raid level and software raid plus the risk of not knowing the system because zfs is designed for solaris engineers to manage, not casual users. Jul 02, 20 software raid is one of the greatest feature in linux to protect the data from disk failure. Zfs is a combined file system and logical volume manager designed by sun microsystems. The solaris management console smc comes with the solaris 9 distribution, and allows you to configure your software raid, among other things.
We have a new solaris 10 server sun fire v240, that we needed for a fiber equipment nms. In solaris 9 the solaris volume manager is your tool for software raid. Up until windows 8, software raid in windows was a mess. There are at least three different practically used raid configurations that are often called levels 0, 1, 5. Zfs is also much faster at raidz that windows is at software raid5. I have seen some of the environments are configured with software raid and lvm volume groups are built using raid devices. Just set up the partitions on one drive, and you can copy the partition info to the other drives. I n this article, we are going to learn how to configure linux lvm in software raid 5 partition. Here is a screenshot of the solaris management console with our raid 5 array we left 1 percent of the drives left for the meta dbs, the other partition was 99%. We have just received a sun ultra 40 box that has 6 drives 2x250gb and 4x500gb i m trying to setup a software raid 5 on the 500gb drives with one spare and also mirror the 250gb drives. I have found some info on how to mirror the 250gb drives but i havent been able to find very detailed on how to setup the raid 5.
The solaris volume manager software uses logical volumes sets of disk slices, to implement raid 0, raid 1, and raid 5. When i say easy in this post, it means that we need calculation as much as raid5 recovery. Sparc t41solaris 11add 2 new hdds in raid 0 configuration. Caution do not create volumes larger than 1 tbyte if you expect to run the solaris software with. Whether software raid vs hardware raid is the one for you depends on what you need to do and how much you want to pay. The high level steps to grow the raid 5 metadevice d10 are. I try make software raid on x86 server with solaris 10. Disk devrdskc0t1d0sx first we must get the partition table from the first disk to the second. We left 1 percent of the drives left for the meta dbs, the other. Software raid 10 in solaris 11, multipath, and a few related questions showing of 3 messages. Software is ready for deployment and customer has a new t41 sparc, but s the unix and linux forums sparc t41solaris 11add 2 new hdds in raid 0 configuration the unix and linux forums. In case of hardware raid, 4x raid10 groups were created each made of 10 disks 40 disks in total and each group presented as a single lun.
So if you set it for raid 5 it acts like raid 5 because it is raid 5. The issues are from using a single device the real raid array and then making a bunch of fake drives on top of it and then using software raid to make those fake drives look like one large drive again. The solaris volume manager administration guide provides instructions on using solaris volume manager to manage disk storage, including creating, modifying, and using raid 0 concatenation and stripe volumes, raid 1 mirror volumes, raid 5 volumes, and soft partitions. Heres another script this one to set up raid 5 relatively easily. Jun, 2016 software raid is used exclusively in large systems mainframes, solaris risc, itanium, san systems found in enterprise computing. As you already know the software raid in solaris is made at the partition level so for example, partition 1 from first disk is mirrored or stripe with partition 1 on the second disk. Mar 06, 2018 older raid controllers disable the builtin fast caching functionality of the ssd that needed for efficient programming and erasing onto the drive. The solaris volume manager software uses logical volumes sets of. Hardware raid will cost more, but it will also be free of software raid s.
Windows 7 has arbitrary restrictions on the available raid levels, and it was impossible to create a level 5 raid without windows server. An quick howto for mirroring your system disk to the 2. Software raid considerations solaris volume manager. Next step is to actually create the raid using these two disks. Here is a screenshot of the solaris management console with our raid 5 array. Currently, the solaris operating system is shipped with a plugin for the mpt driver. However i am a little concerned with the raid 5 rebuild duration problem. In the following explanation, when i say data drive, it means drives with actual data, not parities. So there were 4 luns, two on one storage processor and 2 on the other then zfs striped pool over all 4 luns was. Synology diskstation ds, buffalo terastation, are examples.
The solaris volume manager administration guide provides instructions on using solaris volume manager to manage disk storage, including creating, modifying, and using raid0 concatenation and stripe volumes, raid1 mirror volumes, raid5 volumes, and soft partitions. If this is an option check the webappliances on bsd freenas, nas4free on solaris or a free fork. By joining our community you will have the ability to post topics, receive our newsletter, use the advanced search, subscribe to threads and access many other special features. As we all know that software raid 5 and lvm both are one of the most useful and major features of linux. Windows 10, windows server 2012 r2 or later linux kernel 3. Setting up raid 5 software on solaris 10 in sunfire v250, having 6 hard disk. How to set up software raid1 on a running system incl. For understanding the data recovery in raid, you can consider raid5 as raid4 for now. Raid5 fixed the shortcomings of raid4 by changing the parity drive at every write.
The utility is built on a common library that enables the insertion of plugin modules for different drivers. Software is ready for deployment and customer has a new t41 sparc, but s the unix and linux forums sparc t41 solaris 11add 2 new hdds in raid 0 configuration the unix and linux forums. Zfs equally as mobile between solaris, opensolaris, freebsd, osx, and linux under fuse. The dependency on a software driver is due to the design of raidctl. Raidz is the worlds first softwareonly solution to the raid5 write hole. In solaris 9, a whole raid 0 contains 2 disk must be configure, then, raid 1 mirroring slice by slice inside. We need to setup software raid before the company that supports the fiber nms, will support it. But its not available on windows, only on solaris the origin, bsd, osx and linux. We are running the console remotely, so to run smc on our workstation we have to run. So that graphical application can be launched remotely. Explination about raid levels in solaris 10 describing raid and solaris volume manager software the solaris volume manager software can be run from the command line or a graphical user interface gui tool to simplify system administration tasks on storage devices. Raid 5 fixed the shortcomings of raid 4 by changing the parity drive at every write. Zfs is scalable, and includes extensive protection against data corruption, support for high storage capacities, efficient data compression, integration of the concepts of filesystem and volume management, snapshots and copyonwrite clones, continuous integrity checking and automatic repair, raidz.
Plan to use software raid veritas volume mgr on c1t2d0 disk. I make mirroring all data partitions it normally working. Once that is done tell solaris what to use for the root device the next time you boot. It came with 2 disks but only one disk is being used at present. Now for step 4 attach the primary disk devices to the raid device.
From the enhanced storage tool within the solaris management console, open the volumes node, then choose action. Aug 18, 2019 i n this article, we are going to learn how to configure linux lvm in software raid 5 partition. We have lvm also in linux to configure mirrored volumes but software raid recovery is much easier in disk failures compare to linux lvm. After format and label the disk, still not able to detect using vxdiskadm.
Zfs is scalable, and includes extensive protection against data corruption, support for high storage capacities, efficient data compression, integration of the concepts of filesystem and volume management, snapshots and copyonwrite clones, continuous integrity checking and automatic repair, raid z, native. Hardware raid will cost more, but it will also be free of software raids. Only the single slice can be included in the raid0 volume. Software raid, as you might already know, is usually builtin on your os and unlike a hardware raid, you will need to spend a little extra on a controller card. Software raid in a guest vm, on top of a vmware host. It is used to improve disk io performance and reliability of your server or workstation. I have a sun fire v240 server,now i want to know whether there is a hardware based raid or not. Jan 17, 2018 tiger vnc is a highperformance clientserver application that allows end users to take remote gui session remote desktop of linux servers. We dont have a solaris support contract other than the hardware warranty. But the real question is whether you should use a hardware raid solution or a software raid solution. Oct 10, 2008 zfs equally as mobile between solaris, opensolaris, freebsd, osx, and linux under fuse. Fortunately, it is easy to build a software raid 5 in windows 8.
Tiger vnc is a highperformance clientserver application that allows end users to take remote gui session remote desktop of linux servers. In raid6, we use different methods for different failure scenarios. Find answers to raid 5 on solaris 9 from the expert community at experts exchange. Zfs is also much faster at raid z that windows is at software raid5. This has become much less necessary with more intelligent storage solutions that implement hardware mirroring and raid 5. Software raid in solaris 10 ars technica openforum. On a side note, if youre using software raid its about a million times easier to setup a zfs pool, if you have solaris 10 1106 or later installed. Smbs using nas devices for backup and restore purposes will find many software raid based options. On native platforms not linux solaris is faster that ntfs. The software may include portions offered on terms in addition to those. Create a new raid0 volume on the slice from the previous step by using one of the following methods. Jul 07, 2009 a redundant array of inexpensive disks raid allows high levels of storage reliability. There are six levels of raid as well as a non redundant array of independent disks raid 0.
A raid can be deployed using both software and hardware. May 30, 2017 up until windows 8, software raid in windows was a mess. Software raid is used exclusively in large systems mainframes, solaris risc, itanium, san systems found in enterprise computing. The script has a bit of an affinity for controller 0, but is designed to work with other controllers too except that it wont set the bootdevice in the eeprom for you if your root filesystems arent both on controller 0. Raid 5 uses striping with parity technique to store the data in hard disks. Software mirroring and raid 5 are used to increase the availability of a storage subsystem. For understanding the data recovery in raid, you can consider raid 5 as raid 4 for now. So this may be the best current software raid regarding data security, crash security on a power outage, expandability up to petabyte and performance. But with budget favoring the software raid, those wanting optimum performance and efficiency of raid will have to go with the hardware raid. So i was thinking initially going with 5x1tb sata drives in a raid 5. Software raid not windows but other software raid can be just fine. Smbs using nas devices for backup and restore purposes will find many softwareraid based options. While software raid 5 is really not a good idea for performance, there is sometimes a need to use software mirroring.
1513 437 500 1019 1034 1158 1514 527 379 1617 387 845 839 227 1201 753 433 16 253 680 441 547 1096 520 1367 501 865 1474 1228 290 942 1031 1316 673